Balancing Machines for Small Rotors and Complete Assemblies

  • Complete workplace designed for standing or seated operator
  • Highest balancing accuracy through super-critical support pedestals and digital measurement processing
  • Short change-over times, simple and safe operation
  • Modular design for various applications

Range of application

Universal balancing machines series R and RS are especially suitable for very small work-pieces such as small armatures, miniature ventilators and complete assemblies, when high balancing tolerances at high speed must be achieved. They are used in small production lots as well as research and development applications.

They can be used at varying locations and the change-over for other rotor types is possible in a short time.

Design

Displacement measuring, horizontal balancing machines of tabletop design for standing or seated operator with semi or fully automatic operating sequence.

If the machine is to be used for assemblies, the two support pedestals are connected by a frame. An adapter and clamping arrangement is mounted onto this frame for supporting the rotors.

The drive can be by tangential, under slung, over slung, compressed air or, in case of complete assemblies, by an integrated supply for self-drive.

Sequence of operations

  • Manually load the rotor onto the pedestals and the tangential belt drive. With an over slung belt drive clamp the belt drive bracket.
  • Close the protective device and start the automatic measuring run: accelerate, measure and display the unbalance on the measuring unit, brake. The display is retained after the measuring run ends.
  • Open the protective device, manually correct the unbalance (if required).
  • Check the residual unbalance (the measuring unit displays if the tolerance is achieved) and unloadthe rotor.